Konvision - Bundle: CR250 & CR100
Konvision CR-250-RH-CR-100 - Bundle: CR250 & CR100
1039146
The combination of accurarcy of CR-250 spectroradiometer and the excellent measurement speed as well as the dark part measurement characteristics will help to achieve an ideal result of monitor color correction,compatible with color management softwares such as Lightspace and Calman.
Visuals Price
17,400.00 CHF
VAT excl.
18,809.40 CHF Inc. VAT
Made to order
-
Delivery
- Shipped in 2 to 3 weeks
-
In-store pickup
- Available in 2 to 3 weeks
CR-100 and CR-250-RH Chromameter and Spectroradiometer Pack
The combination of the CR-250 spectroradiometer's precision and the CR-100's excellent measurement speed, along with dark area measurement characteristics, will provide an ideal result for colour correction of monitors, compatible with colour management software such as Lightspace and Calman. Colorimetry Research's CR-100 is a high-quality chromameter.
The CR-100 uses an all-aluminium and stainless steel construction that guarantees excellent durability, with a compact and lightweight design of only 340 grammes. It uses a trichromatic stimulus filter and a four-colour matrix algorithm to improve colour measurement accuracy with a wavelength range of 380 to 780 nm, compatible with colour management software such as Lightspace and Calman.
|
Specifications |
|
|
|
Portable recorder |
||
|
Weight |
0.45 kg | |
|
Wavelength range |
380 - 780 nm |
|
| Luminance range | 0.001 fL - 1,500 fL 0.0002 fL at signal-to-noise ratio > 10, 20 s exposure 0.001 fL at signal-to-noise ratio > 10, 0.5 s exposure 0.001 fL at signal-to-noise ratio > 100, 20 s exposure 1,500 fL at signal-to-noise ratio > 8,000, 1 s exposure |
|
| Luminance accuracy | ± 2% at 0.1 fL, 0.4 s exposure | |
| Luminance repeatability | 0.2% at 0.1 fL, 0.4 s exposure 1.5% at 0.01 fL, 0.5 s exposure 1.5% at 0.001 fL, 20 s exposure |
|
| Luminance range | 0.17 cd/m² - 154,000 cd/m² (0.05 fL - 45,000 fL)≠ | |
| Chromatic accuracy | ± 0.0015 x, y at 0.1 fL, 0.4 s exposure ± 0.0015 x, y at 0.02 fL, 20 s exposure |
|
|
Chromatic repeatability |
0.0005 x, y at 0.1 fL, 0.4 s exposure 0.0005 x, y at 0.02 fL, 20 s exposure |
|
| Polarisation error |
≤ 0.1% |
|
| Synchronisation frequency | 10 - 500 Hz (custom synchronisation frequency 10 Hz | |
| Synchronisation frequency |
Direct observation and measurement system |
|
|
Exposure time range |
1 ms - 20 s |
|
|
Voltage |
5 V/120 mA (600 mW) via USB 2.0 | |
| Interface | USB 2.0 |
|
| Weight | 0.34 kg | |
|
Viewing optics |
Patent pending for mobile and rotating display system |
|
|
Custom synchronisation |
10 - 10,000 Hz | |
|
Exposure time range |
0.04 - 30 s | |
|
Voltage |
15 V/120 mA (600 mW) via USB 2.0 | |
|
Interface |
USB 2.0 | |
|
Weight |
1.134 kg |
Loading...